Uplink Setup

Step

Procedure

Troubleshooting

1

Apply a 70 MHz (140 MHz) signal at a
known level between –25 and –45
dBm to the IF IN (J3) connector of the
KST-2000A/B.

The AGC function is selected as ON.
The AGC will not function below a
– 45 dBm input level.

1. If the AGC function is selected as

OFF, lower input levels can be
used limited only by noise.

2. See Section 3.12 for more infor-

mation on the AGC function.

2

Set the up converter to the desired RF
TX frequency using the appropriate
commands from the KP10 terminal, or
Windows

™ M&C.

1. See the up converter frequency

select command (Appendix B.3).

2. If an error message is received,

see Appendix B.2.3 to determine
the cause.

3

Before proceeding, ensure that the
HPA is properly terminated.

If a directional coupler and termina-
tion is used or an attenuator is used,
note the value.

4

Enable external faults, execute the
appropriate HPA Power and Heater
commands

See Appendix B.4 HPA commands.

5

Turn the RF output of the up converter
ON.

1. See Appendix B.3 system con-

figuration commands.

2. There should be no up converter

faults at this time.

6

Using an appropriate frequency meas-
uring device, ensure that the output of
the HPA (measured through the cou-
pler or attenuator) is at the correct fre-
quency.

1. If an external 5 or 10 MHz source

is used, the internal reference
will automatically frequency-lock
to it.

2. Ensure that there are no reported

reference faults using the com-
mands in Appendix B.9, Refer-
ence Current Faults.

3. If the internal, high-stability oscil-

lator is used, its frequency can
be fine tuned using the reference
frequency adjust command.

4. See Appendix B.3. Allow at least

30 minutes warm-up before ad-
justing the oscillator.

7

Using an appropriate RF power meas-
uring device, set the up converter at-
tenuation until the power measured at
the output of the coupler or attenuator
is at the correct value.

See Appendix B.3.

8

Turn the RF output of the up converter
off.

See Appendix B.3.