beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 173

background image

Ku-Band Satellite Transceiver

Revision 9

FSK Remote Control Commands

MN/KST2000AB.IOM

E-21

Parameter
Type

Command
(Instruction
Code and
qualifier)

Arguments for
Command or
Response to
Query

Description of arguments
(note that all arguments are ASCII numeric codes, that is,
ASCII codes between 48 and 57)

Response to Command (target to
controller)

Query
(Instruction
Code and
qualifier)

Reference Stored
Faults

n.a.

6 bytes

Query only.
>add/RSF=ABCDEF’cr’’lf’ or
>add/RSF=NO_FAULT’cr’’lf’


Where: A=REF Source, 0=OK, 1=FLT

B=Oscillator State, 0=COLD, 1=EXT
C=72M Lock Status, 0=OK, 1=FLT
D=EXT REF Lock Status, 0=OK, 1=FLT
E=EXT REF Phase_N Status, 0=OK,
1=FLT, 2=NA
F=EXT REF Range Status, 0=OK,
1=FLT, 2=NA
X=Stored Fault Locations (0 to 9)

RSF= (message ok)
RSF? (received ok, but invalid arguments
found)
RSF* (message ok, but not permitted in
current mode)

RSF?

HPA Stored
Faults (2 and 4
Watt)

n.a.

5 bytes

Query only.
>add/HSF=ABCDE’cr’’lf’ or
>add/HSF=NO_FAULT’cr’’lf’


Where: A=Overtemperature Status, 0=OK, 1=FLT

B=9.75V Status, 0=OK, 1=FLT
C=-5V Status, 0=OK, 1=FLT
D=BV1 Summary Status, 0=OK, 1=FLT
E=Interprocessor Comm.Status, 0=OK, 1=FLT
X=Stored Fault Locations (0 to 9)

HSF= (message ok)
HSF? (received ok, but invalid arguments
found)
HSF* (message ok, but not permitted in
current mode)

HSF?