beautypg.com

Comtech EF Data KST-2000A/B User Manual

Page 119

background image

Ku-Band Satellite Transceiver

Revision 9

Terminal Mode Commands

MN/KST2000AB.IOM

B–9

System
Maintenance
Status

Command
Response

>add/MS_’cr’
UCT_nn’cr’
HPT_nn’cr’
DCT_nn’cr’
MCT_nn’cr’
PRF_nn’cr’
FTD_xxx’cr’
HV_xxx’cr’’lf’]

Where:

nn = UC Temperature in

°C

nn = HPA Temperature in

°C

nn = DC Temperature in

°C

nn = M&C Temperature in

°C

nn = Comtech EF Data HPA corrected RF

output

power

N/A = OEM SSPA

N/A = OEM TWTA

xxx = (OK/DLY or N/A) OEM TWTA only,

Heater

timer

complete

xxx = ON/OFF or N/A OEM TWTA only,

high

voltage

status

Up Converter
Current Faults

Command
Response

>add/US_’cr’
RF_xxx’cr’
UC_xxx’cr’
SSYN_xxx’cr’
KSYN_xxx’cr’
LSSYN_xxx’cr’
LKSYN_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]



RF Output (ON/OFF) Actual Status
Up Converter Module (OK/FLT)
S-Band Synthesizer Lock Detect (OK/FLT)
Ku-Band Synthesizer Lock Detect (OK/FLT)
Latched S-Band Synthesizer Lock Detect (OK/FLT)
Latched Ku-Band Synthesizer Lock Detect (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)

HP Current Faults
2 and 4 Watt
SSPAs
Current Faults

(Comtech EF
Data)

Command
Response

>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]



RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)

HP Current Faults
8 Watt SSPAs
Current Faults

(Comtech EF
Data)

Command
Response

>add/HS_’cr’

RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]



RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)

HP Current
Faults
16 Watt SSPAs
Current Faults

(Comtech EF
Data)

Command
Response

>add/HS_’cr’
RF_xxx’cr’
HPA_xxx’cr’
BV1_xxx’cr’
BV2_xxx’cr’
BV3_xxx’cr’
BV4_xxx’cr’
BV5_xxx’cr’
+9.75V_xxx’cr’
-5V_xxx’cr’
PROG_xxx’cr’
SFLT_#’cr’’lf’]



RF Output (ON/OFF) Actual Status
HPA Converter Module (OK/FLT)
Bias Voltage #1 (OK/FLT)
Bias Voltage #2 (OK/FLT)
Bias Voltage #3 (OK/FLT)
Bias Voltage #4 (OK/FLT)
Bias Voltage #5 (OK/FLT)
+9.75 V Power Supply (OK/FLT)
–5 Volt Power Supply (OK/FLT)
Inter-processor Communications (OK/FLT)
Number of stored faults (# = 1 to 10)