Installation
EL7037-0000
LEDs
No.
LED
Color
Meaning
1
RUN
green
This LED indicates the terminal's operating state:
off
State of the EtherCAT State Machine: INIT =
Initialization of the terminal or BOOTSTRAP =
Function for firmware updates of the terminal
blinking
State of the EtherCAT State Machine: PREOP =
Setting for mailbox communication and variant
standard settings
single flash
State of the EtherCAT State Machine: SAFEOP =
Channel checking of the Sync Manager and the
Distributed Clocks. Outputs stay in safe operation
mode.
on
State of the EtherCAT State Machine: OP = Normal
operation mode, mailbox- and process data
communication possible
2
Encoder
green
on
Encoder ready for operation
3
A
green
on
Signal at encoder input A
4
B
green
on
Signal at encoder input B
5
C
green
on
Signal at encoder input C
6
Latch
green
on
Signal at latch input
7
Turn CW
green
on
Motor is triggered clock wise
8
Input 1
green
on
Signal at digital input 1
9
Driver
green
on
Driver stage ready for operation
10
Power
green
off
The power supply voltage (24 V
DC
) is absent or
the motor control is blocked (Index 6010:02 [
not set))
on
The power supply voltage (24 V
DC
) is present
11
Warning
yellow
on
Configuration error, e.g.:
• Motor power supply not connected
• 80°C temperature exceeded
• 100% duty cycle reached
• ...
12
Error A
red
on
Configuration error of output stage A, e.g.:
• 100°C temperature exceeded
• short circuit
• ...
13
Error B
red
on
Configuration error of output stage B, e.g.:
• 100°C temperature exceeded
• short circuit
• ...
14
Enable
green
off
The motor control is blocked (Index 6010:02 [
185] is
not set) or EL7037 is not ready for operation
on
The motor control is activated (Index 6010:02 [
is set) or EL7037 is ready for operation
15
Turn CCW
green
on
Motor is triggered counter clock wise
16
Input 2
green
on
Signal at digital input 2
EL70x7
49