Index 8021 POS Features Ch.1
Index
Name
Meaning
Data type
Flags
Default value
8021:0
POS Features
Ch.1
Maximum subindex
UINT8
RO
0x16 (22
dec
)
8021:01
Start type
permitted values:
UINT16
RW
0x0001 (1
dec
)
0: Idle
1: Absolute
2: Relative
3: Endless plus
4: Endless minus
6: Additive
24832: Calibration (Hardware sync)
24576: Calibration (Plc cam)
28416: Calibration (Clear manual)
28160: Calibration (Set manual)
28161: Calibration (Set manual auto)
1029: Modulo current
773: Modulo minus
517: Modulo plus
261: Modulo short
8021:11
Time information
permitted values:
BIT2
RW
0x00 (0
dec
)
0: Elapsed time
current drive time since start of the travel command
8021:13
Invert calibration
cam search direc-
tion
Inversion of the direction of rotation towards the cam
BOOLEAN
RW
0x01 (1
dec
)
8021:14
Invert sync im-
pulse search di-
rection
Inversion of the direction of rotation away from the cam
BOOLEAN
RW
0x00 (0
dec
)
8021:15
Emergency stop
on position lag er-
ror
Triggers an emergency stop if the maximum following er-
ror is exceeded
BOOLEAN
RW
0x00 (0
dec
)
8021:16
Enhanced diag
history
Provides detailed messages about the status of the posi-
tioning interface in the diag history
BOOLEAN
RW
0x00 (0
dec
)
Command object
Index FB00 STM Command
Index
Name
Meaning
Data type
Flags
Default value
FB00:0
STM Command
Maximum subindex
UINT8
RO
0x03 (3
dec
)
FB00:01
Request
Requesting a command
0x8000: Software reset
OCTET-
STRING[2]
RW
{0}
FB00:02
Status
Status of the command
UINT8
RO
0x00 (0
dec
)
0: No error, without return value
1: No error, with return value
2: With error, without return value
3: With error, with return value
... reserved
255: Command execution active
FB00:03
Response
Return value of the executed command
OCTET-
STRING[4]
RO
{0}
EL70x7