1 el7037, Object description and parameterization – BECKHOFF EL7037 User Manual
Page 155

Configuration by means of the TwinCAT System Manager
6
Configuration by means of the TwinCAT System
Manager
6.1
EL7037
6.1.1
Object description and parameterization - Profile-specific
objects
Note
EtherCAT XML Device Description
The display matches that of the CoE objects from the EtherCAT XML Device Description.
We recommend downloading the latest XML file from the download area of the
website
Note
Parameterization via the CoE list (CAN over EtherCAT)
The terminal is parameterized via the CoE - Online tab (double-click on the respective ob-
ject) or via the Process Data tab (allocation of PDOs). Please note the following general
CoE information [
32] when using/manipulating the CoE parameters:
- Keep a startup list if components have to be replaced
- Differentiation between online/offline dictionary, existence of current XML description
- use "CoE reload" for resetting changes
Attention
Risk of damage to the device!
We strongly advise not to change settings in the CoE objects while the axis is active, since
this could impair the control.
Introduction
The CoE overview contains objects for different intended applications:
Object overview
• Information / diagnostic data (channel specific) [
• Manufacturer configuration data (device-specific) [
• Information / diagnostic data (device-specific) [
Restore object
Index 1011 Restore default parameters
Index
Name
Meaning
Data type
Flags
Default value
1011:0
Restore default
parameters
Restore default parameters
UINT8
RO
0x01 (1
dec
)
1011:01
SubIndex 001
If this object is set to "0x64616F6C" in the set value dia-
log, all backup objects are reset to their delivery state.
UINT32
RW
0x00000000 (0
dec
)
EL70x7
155
Version 1.0