Error correction
Text ID Type
Place
Text (English
only)
Cause
0x82FF Error
Communicatio
n
Boot mode not activated
0x8300
Error
Encoder
Error while setting the position
0x8301
Error
Encoder
Encoder increments not configured
0x8302
Error
Encoder
Feedback-Error
The amplitude of the resolver is too small
0x8400
Error
Drive
Drive incorrectly configured
0x8401
Error
Drive
Limitation of the calibration velocity
0x8402
Error
Drive
Emergency stop activated
0x8403
Error
Drive
ADC Error
Error during current measurement in the
ADC
0x8404
Error
Drive
Overcurrent
Overcurrent in phase U, V or W
0x8405
Error
Drive
Modulo position invalid
0x8406
Error
Drive
DC-Link
undervoltage
(Error)
The DC link voltage of the terminal is lower
than the parameterised minimum voltage.
Activation of the output stage is prevented
0x8407
Error
Drive
DC-Link
overvoltage (Error)
The DC link voltage of the terminal is higher
than the parameterised maximum voltage.
Activation of the output stage is prevented
0x8408
Error
Drive
I2T-Model Amplifier
overload (Error)
- The amplifier is being operated outside the
specification
- The I2T-model of the amplifier is
incorrectly parameterised
0x8409
Error
Drive
I2T-Model motor
overload (Error)
- The motor is being operated outside the
parameterised rated values
- The I2T-model of the motor is incorrectly
parameterised
0x8415
Error
Drive
Modulo factor invalid
EL70x7
207