To this end set the index 8010:01, 180] "nominal voltage" in the, Can be set in index 8010:02 – BECKHOFF EL7037 User Manual
Page 180

Configuration by means of the TwinCAT System Manager
Index 8000 ENC Settings Ch.1
Index
Name
Meaning
Data type
Flags
Default value
8000:0
ENC Settings
Ch.1
Maximum subindex
UINT8
RO
0x0E (14
dec
)
8000:08
Disable filter
Deactivates the input filters.
BOOLEAN
RW
0x00 (0
dec
)
8000:0A
Enable micro in-
crements
The lower 8 bits of the counter value are extrapolated.
BOOLEAN
RW
0x00 (0
dec
)
8000:0E
Reversion of rota-
tion
Activates reversion of rotation of the encoder.
BOOLEAN
RW
0x00 (0
dec
)
Index 8010 STM Motor Settings Ch.1
Index
Name
Meaning
Data type
Flags
Default value
8010:0
STM Motor Set-
tings Ch.1
Maximum subindex
UINT8
RO
0x0A (10
dec
)
8010:01
Maximal current
Maximum permanent motor coil current
Unit: 1 mA
UINT16
RW
0x1388 (5000
dec
)
8010:02
Reduced current
Reduced coil current
Unit: 1 mA
UINT16
RW
0x09C4 (2500
dec
)
8010:03
Nominal voltage
Nominal voltage (supply voltage) of the motor
Unit: 10 mV
UINT16
RW
0x1388 (5000
dec
)
8010:04
Motor coil resis-
tance
Internal resistance of the motor
Unit: 10 mOhm
UINT16
RW
0x0064 (100
dec
)
8010:05
Motor EMF
Countervoltage of the motor
Unit: 1 mV / (rad/s)
UINT16
RW
0x0000 (0
dec
)
8010:06
Motor fullsteps
Number of full motor steps
UINT16
RW
0x00C8 (200
dec
)
8010:07
Encoder incre-
ments (4-fold)
Number of encoder increments per revolution with
quadruple evaluation
UINT16
RW
0x1000 (4096
dec
)
8010:09
Start velocity
Minimum starting velocity of the motor
Unit: 10000 corresponds to 100% [
UINT16
RW
0x0000 (0
dec
)
8010:0A
Motor coil induc-
tance
Inductance of the motor
Unit: 0.01 mH
UINT16
RW
0x0000 (0
dec
)
8010:10
Drive on delay
time
Delay between activation of driver stage and
„ready = 1“
UINT16
RW
0x0064 (100dez)
8010:11
Drive off delay
time
Delay between deactivation of driver stage and
„ready = 0“
UINT16
RW
0x0096 (150dez)
Index 8011 STM Controller Settings Ch.1
Index
Name
Meaning
Data type
Flags
Default value
8011:0
STM Controller
Settings Ch.1
Maximum subindex
UINT8
RO
0x02 (2
dec
)
8011:01
Kp factor (curr.)
Kp control factor of the current controller
UINT16
RW
0x0096 (150
dec
)
8011:02
Ki factor (curr.)
Ki control factor of the current controller
UINT16
RW
0x000A (10
dec
)
EL70x7
180
Version 1.0