Index 8000 ENC Settings Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8000:0

ENC Settings
Ch.1

Maximum subindex

UINT8

RO

0x0E (14

dec

)

8000:08

Disable filter

Deactivates the input filters.

BOOLEAN

RW

0x00 (0

dec

)

8000:0A

Enable micro in-
crements

The lower 8 bits of the counter value are extrapolated.

BOOLEAN

RW

0x00 (0

dec

)

8000:0E

Reversion of rota-
tion

Activates reversion of rotation of the encoder.

BOOLEAN

RW

0x00 (0

dec

)

Index 8010 STM Motor Settings Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8010:0

STM Motor Set-
tings Ch.1

Maximum subindex

UINT8

RO

0x0A (10

dec

)

8010:01

Maximal current

Maximum permanent motor coil current
Unit: 1 mA

UINT16

RW

0x1388 (5000

dec

)

8010:02

Reduced current

Reduced coil current
Unit: 1 mA

UINT16

RW

0x09C4 (2500

dec

)

8010:03

Nominal voltage

Nominal voltage (supply voltage) of the motor
Unit: 10 mV

UINT16

RW

0x1388 (5000

dec

)

8010:04

Motor coil resis-
tance

Internal resistance of the motor
Unit: 10 mOhm

UINT16

RW

0x0064 (100

dec

)

8010:05

Motor EMF

Countervoltage of the motor
Unit: 1 mV / (rad/s)

UINT16

RW

0x0000 (0

dec

)

8010:06

Motor fullsteps

Number of full motor steps

UINT16

RW

0x00C8 (200

dec

)

8010:07

Encoder incre-
ments (4-fold)

Number of encoder increments per revolution with
quadruple evaluation

UINT16

RW

0x1000 (4096

dec

)

8010:09

Start velocity

Minimum starting velocity of the motor
Unit: 10000 corresponds to 100% [

}

 126]

UINT16

RW

0x0000 (0

dec

)

8010:0A

Motor coil induc-
tance

Inductance of the motor
Unit: 0.01 mH

UINT16

RW

0x0000 (0

dec

)

8010:10

Drive on delay
time

Delay between activation of driver stage and
„ready = 1“

UINT16

RW

0x0064 (100dez)

8010:11

Drive off delay
time

Delay between deactivation of driver stage and
„ready = 0“

UINT16

RW

0x0096 (150dez)

Index 8011 STM Controller Settings Ch.1

Index

Name

Meaning

Data type

Flags

Default value

8011:0

STM Controller
Settings Ch.1

Maximum subindex

UINT8

RO

0x02 (2

dec

)

8011:01

Kp factor (curr.)

Kp control factor of the current controller

UINT16

RW

0x0096 (150

dec

)

8011:02

Ki factor (curr.)

Ki control factor of the current controller

UINT16

RW

0x000A (10

dec

)

EL70x7