Configuration by means of the TwinCAT System Manager
Index 8020 POS Settings Ch.1
Index
Name
Meaning
Data type
Flags
Default value
8020:0
POS Settings
Ch.1
Maximum subindex
UINT8
RO
0x10 (16
dec
)
8020:01
Velocity min.
Minimum set velocity (range: 0-10000)
INT16
RW
0x0064 (100
dec
)
8020:02
Velocity max.
Maximum set velocity (range: 0-10000)
INT16
RW
0x2710 (10000
dec
)
8020:03
Acceleration pos. Acceleration in positive direction of rotation
Unit: 1 ms
UINT16
RW
0x03E8 (1000
dec
)
8020:04
Acceleration neg. Acceleration in negative direction of rotation
Unit: 1 ms
UINT16
RW
0x03E8 (1000
dec
)
8020:05
Deceleration pos. Deceleration in positive direction of rotation
Unit: 1 ms
UINT16
RW
0x03E8 (1000
dec
)
8020:06
Deceleration neg. Deceleration in negative direction of rotation
Unit: 1 ms
UINT16
RW
0x03E8 (1000
dec
)
8020:07
Emergency decel-
eration
Emergency deceleration (both directions of rotation)
Unit: 1 ms
UINT16
RW
0x0064 (100
dec
)
8020:08
Calibration posi-
tion
Calibration position
UINT32
RW
0x00000000 (0
dec
)
8020:09
Calibration veloc-
ity (towards plc
cam)
Calibration velocity towards the cam (range: 0-10000)
INT16
RW
0x0064 (100
dec
)
8020:0A
Calibration Veloc-
ity (off plc cam)
Calibration velocity away from the cam (range: 0-10000)
INT16
RW
0x000A (10
dec
)
8020:0B
Target window
Target window
UINT16
RW
0x000A (10
dec
)
8020:0C
In-Target timeout
Target position timeout
Unit: 1 ms
UINT16
RW
0x03E8 (1000
dec
)
8020:0D
Dead time com-
pensation
Dead time compensation
Unit: 1 µs
INT16
RW
0x0032 (50
dec
)
8020:0E
Modulo factor
Modulo factor/position
UINT32
RW
0x00000000 (0
dec
)
8020:0F
Modulo tolerance
window
Tolerance window for modulo positioning
UINT32
RW
0x00000000 (0
dec
)
8020:10
Position lag max.
Maximum allowable step error
UINT16
RW
0x0000 (0
dec
)
EL70x7
159
Version 1.0