And the “pos features” (index 8021, Index 8021:13, Index 8021:14 – BECKHOFF EL7037 User Manual
Page 184: 184]) away from the cam. after the, Command object, Command object index fb00 stm command

Configuration by means of the TwinCAT System Manager
Index 8021 POS Features Ch.1
Index
Name
Meaning
Data type
Flags
Default value
8021:0
POS Features
Ch.1
Maximum subindex
UINT8
RO
0x16 (22
dec
)
8021:01
Start type
permitted values:
UINT16
RW
0x0001 (1
dec
)
0: Idle
1: Absolute
2: Relative
3: Endless plus
4: Endless minus
6: Additive
24832: Calibration (Hardware sync)
24576: Calibration (Plc cam)
28416: Calibration (Clear manual)
28160: Calibration (Set manual)
28161: Calibration (Set manual auto)
1029: Modulo current
773: Modulo minus
517: Modulo plus
261: Modulo short
8021:11
Time information
permitted values:
BIT2
RW
0x00 (0
dec
)
0: Elapsed time
current drive time since start of the travel command
8021:13
Invert calibration
cam search direc-
tion
Inversion of the direction of rotation towards the cam
BOOLEAN
RW
0x01 (1
dec
)
8021:14
Invert sync im-
pulse search di-
rection
Inversion of the direction of rotation away from the cam
BOOLEAN
RW
0x00 (0
dec
)
8021:15
Emergency stop
on position lag er-
ror
Triggers an emergency stop if the maximum following er-
ror is exceeded
BOOLEAN
RW
0x00 (0
dec
)
8021:16
Enhanced diag
history
Provides detailed messages about the status of the posi-
tioning interface in the diag history
BOOLEAN
RW
0x00 (0
dec
)
Command object
Index FB00 STM Command
Index
Name
Meaning
Data type
Flags
Default value
FB00:0
STM Command
Maximum subindex
UINT8
RO
0x03 (3
dec
)
FB00:01
Request
Requesting a command
0x8000: Software reset
OCTET-
STRING[2]
RW
{0}
FB00:02
Status
Status of the command
UINT8
RO
0x00 (0
dec
)
0: No error, without return value
1: No error, with return value
2: With error, without return value
3: With error, with return value
... reserved
255: Command execution active
FB00:03
Response
Return value of the executed command
OCTET-
STRING[4]
RO
{0}
EL70x7
184
Version 1.0