Status messages

Problem

Meaning

How to solve

ST46

Wrong bar code number

Easy Plug: Invalid bar code number
within the #YB command. The status
message disappears automatically after
3 s. Afterwards, the printer continues
printing.
The label layout is printed without the
relevant bar code.
Check command and recreate.

ST47

Faulty Pharmacy Code

The bar code information given within
the Easy-Plug command contains invalid
characters or has an invalid length. The
status message disappears
automatically after 3 s. Afterwards, the
printer continues printing.
The label layout is printed without the
relevant bar code.
Check command and recreate.

ST50

Read error by scanner

Check scanner

Check print quality

ST51

Scanner can not be programmed

switch off and on the scanner if you have
no success call the service centre

ST59

Factory Reset has been done
before

if factory reset is wanted – do it – all data
are lost

ST60

Memory allocation error

switch ON/OFF the printer

if not helpful call service technician

ST61

Font allocation error

Disconnection and re-connection

Call customer service if error cannot be
eliminated
Caution:

Allow for at least 60

seconds between disconnection and re-
connection.

ST62

Label is to long or to much
commands sent (Auto-
Acknowledgement)

Correct length of label or extend memory
(remove cards not in use ore reduce
spooler size)

Remove some commands

ST69

Not initialised interruption

Disconnect and re-connect
Caution:

Allow for at least 60

seconds between disconnection and re-
connection.