Status messages
Problem
Meaning
How to solve
ST46
Wrong bar code number
Easy Plug: Invalid bar code number
within the #YB command. The status
message disappears automatically after
3 s. Afterwards, the printer continues
printing.
The label layout is printed without the
relevant bar code.
Check command and recreate.
ST47
Faulty Pharmacy Code
The bar code information given within
the Easy-Plug command contains invalid
characters or has an invalid length. The
status message disappears
automatically after 3 s. Afterwards, the
printer continues printing.
The label layout is printed without the
relevant bar code.
Check command and recreate.
ST50
Read error by scanner
Check scanner
Check print quality
ST51
Scanner can not be programmed
switch off and on the scanner if you have
no success call the service centre
ST59
Factory Reset has been done
before
if factory reset is wanted – do it – all data
are lost
ST60
Memory allocation error
switch ON/OFF the printer
if not helpful call service technician
ST61
Font allocation error
Disconnection and re-connection
Call customer service if error cannot be
eliminated
Caution:
Allow for at least 60
seconds between disconnection and re-
connection.
ST62
Label is to long or to much
commands sent (Auto-
Acknowledgement)
Correct length of label or extend memory
(remove cards not in use ore reduce
spooler size)
Remove some commands
ST69
Not initialised interruption
Disconnect and re-connect
Caution:
Allow for at least 60
seconds between disconnection and re-
connection.