beautypg.com

4 ifac: interface parameter, Ifac: interface parameter, Alx 720 – Avery Dennison ALX 720 User Manual

Page 68

background image

Operators Manual

ALX 720

4/09

Page 68

Printer adjustment

Example:

Self adhesive material with a black bar across the label

Measured

values:

Backing

paper

30

Backing

paper

+

label: 60

Backing paper + label + black bar: 190

Value to be adjusted:

60, i.e. all measured values higher than 60 will be ignored,

as well the black bar ( = 190)


„Auto“

at materials with one contrast area = gap within a label

„MAN“ + „F x“

at material with several, different contrast areas

6.4 IFAC: Interface Parameter

In this submenu the settings for the communication ports are done.

Type of interface ________________________________________________ PORT

For normal communication the RS232 connection is used. Only downloading a new program
has to be done via the centronics interface.
„RS23“

Serial interface (V24/DB25, RS232)

„CENT“

Parallel interface (Centronics)

Selection of Spooler Size __________________________________________SPOL

The spooler size can be selected in accordance with requirements specific to the customer. It
influences the maximum print format if no RAM card is used for storage extension.
„8KB“

8kbyte, same for 16,32,64 KB

CAUTION! - All data stored in the printer buffer are cleared!

Spooler Mode ___________________________________________________ BMOD

By this mode of operation execution of single print series ( the interface is only ready for
reception after printout of the desired label quantity ) in accordance with the requirements
specific to the customer can be defined, or whether printing data can be received from the
spooler during printing of multiple series.
„BOF“ Single print series mode
„BON“Multiple print series mode

Filter for characters <20H __________________________________________ <20H

YES Filter enabled. Characters with a hex number below 20H will be filtered out of the data
stream.

NO

Filter disabled. Characters with a hex number below 20H are treated as normal

characters.