Printer adjustment

Entry of password for authorised access

A = NEXT, NEXT, FEED, ON/OFF

B = FEED, ON/OFF, NEXT, FEED, FEED

Corresponds to authorised access, no entry required

Check of entered password

Access time An entered password - A or B - is active until reset or re connection of printer

Access level adjustment - COD0, COD1, COD2 is of resident effectiveness until the
next alteration

Value of print head resistor _______________________________________ HRES

In order to optimise the print quality the value of the head resistor (noted at print head -
11,4 dot/mm print head = 1000 - 1500 Ohm) has to be keyed in when exchanging the print
head.

CAUTION! - The machine is connected to mains. Only authorised personnel
may open the cover. Operation without this cover is not allowed.

This adjustment is not affected when performing the factory setting. Take readings of value and
key in accordingly

„XXXX“

Possible value is between „1000“ and „1500“

Lowering the head temperature _____________________________________HEAT

Printing full-surface print images inordinately heats up the print head, and therefore also the
thermal transfer ribbon. In order to ensure a uniformly good print image, the parameter HEAT is
used to decrease the power supply proportionately to the temperature of the print head.

xxHR

Value range: 00 to 50; unit interval: 10; default: 00
xx = 00 No temperature reduction
xx = 10, 20, ..., 80 up to 10, 20, ..., 80 percent temperature reduction if the print

head is hot

Offset for head voltage ___________________________________________ HVOF

Here an offset value can be added to the value transmitted by the printer (#HV or #!H) to allow
for different printer properties.

Xxxx

Values from -50 to +50 are possible (display -50 ... 0 ... 50)

Progression Unit interval = 1