beautypg.com

2 applicator modes, Applicator modes 10.2.1, Signals for direct dispense – Avery Dennison ALX 720 User Manual

Page 100: Alx 720, Operators manual, 1 signals for direct dispense

background image

Operators Manual

ALX 720

4/09

Page 100

Connections and signals

10.2 Applicator modes

The machine is able to dispense the label direct

on the passing product. There is also the

possibility to drive without any external control a wide range of applicators.

10.2.1 Signals for direct dispense

For direct dispensing the airstream signal can be used to control a pneumatic driven dispensing
edge. The start of the airstream signal (= motor run signal) could be behind the start of the
dispense motor, adjusted with the function APT3. The signal is switched inactive, when the
label dispense has been completed. Also the stop could be adjusted with the function ASTP to
switch inactive before or behind the dispense motor stop.

Ready

Product start

Label start
Suppression

Product start
Suppression

Dispense

Motor run
signal

1

2

3

4

POS

POS

POS

PRDL

APT3

ASTP

ASTP

1

Productstart disabled. PRDL activ

2

Missing Label: New start of dispense during dispenser activ

3

Inhibit activ

4

Machine not ready. Errorcondition or not online

Figure 18 Timing diagram direct dispense