Printer adjustment
CAUTION! - In case the value without materials is > 5 or with material <10
clean sensor by means of pressure air. If this fails, call service technician.
Rxxx
Dancer sensor
< 85
=
home position
200-240 =
end
position
If this sensor is not installed the display shows „R255“
Fxxx
Foil
sensor
0 or 15
=
admissible values on rotation of the ribbon unwind mandrel
Hxxx
Print head sensor
0 =
Print head lifted
15 =
Print head down
Txxx Temperature sensor
not in use with actual firmware
Mxxx Material end sensor
0 =
without
material
15 =
with material
Demo printout __________________________________________________ PCHK
Continuously running demo printout.
(ON/OFFLINE)-key
If print is to be started
(Execution will be acknowledged by a hoot signal)
(FEED) or (NEXT)-key
If print is not to be started
(ON/OFFLINE)-key
Start respectively stop Demo Printout by key
Adjustment to Factory Setting ______________________________________FACT
All parameters are overwritten by factory settings.
The respective actual adjustment can be checked via the Info Printout „STA0“ (see also Info
Printouts „STA0“).
Note: All data in buffer including those from an interrupted print job will be
cancelled!
(ON/OFFLINE) key
All parameters are to be adjusted to factory setting.
(execution will be acknowledged by a hoot signal)
(FEED) or (NEXT) key
Parameters are not to be changed