Operators Manual

ALX 720

4/09

Page 79

Printer adjustment

CAUTION! - In case the value without materials is > 5 or with material <10
clean sensor by means of pressure air. If this fails, call service technician.

Rxxx

Dancer sensor

< 85

=

home position

200-240 =

end

position

If this sensor is not installed the display shows „R255“

Fxxx

Foil

sensor

0 or 15

=

admissible values on rotation of the ribbon unwind mandrel

Hxxx

Print head sensor

0 =

Print head lifted

15 =

Print head down

Txxx Temperature sensor

not in use with actual firmware

Mxxx Material end sensor
0 =

without

material

15 =

with material

Demo printout __________________________________________________ PCHK

Continuously running demo printout.

(ON/OFFLINE)-key

If print is to be started

(Execution will be acknowledged by a hoot signal)

(FEED) or (NEXT)-key

If print is not to be started


(ON/OFFLINE)-key

Start respectively stop Demo Printout by key

Adjustment to Factory Setting ______________________________________FACT

All parameters are overwritten by factory settings.
The respective actual adjustment can be checked via the Info Printout „STA0“ (see also Info
Printouts „STA0“).

Note: All data in buffer including those from an interrupted print job will be
cancelled!

(ON/OFFLINE) key

All parameters are to be adjusted to factory setting.

(execution will be acknowledged by a hoot signal)

(FEED) or (NEXT) key

Parameters are not to be changed