beautypg.com

3 plug board, Plug board, Alx 720 – Avery Dennison ALX 720 User Manual

Page 14

background image

Operators Manual

ALX 720

4/09 Page

14

Description

2.3 Plug board

On the side a plate contains all plugs for external connections. If you use the optional
connections, it is strongly recommended to do this by means of the optional available SUB-D
connectors. This ensures best EMI stability of the machine.

There is one unit include the mains switch, the mains cable socket and the fuses. The fuse
holder setting you have to select according to your local main voltage (100, 120, 220 or 240 V).
You carry this out by taking off the fuse holder and position the fuse holder insert accordingly.

Figure 4 Main switch and printer interface


The plug at the top of the plate are the connections to the dispenser unit. Standard execution in
this machine is one I/O plug prepared for the product sensor and for the applicator. There are
some more holes for optional functions. The connections of the plugs are described in chapter
“connections”.

serial interface printer

mains power plug

mains power switch

mains fuse block