Dispenser adjustment

Note: Modified parameter values are only stored if the menu is left by using the
QUIT function. If the power is switched off before leaving the menu by quit all
modifications are lost

.

5.6 Product data bank

If parameters have to be changed because of different products and labels, the product menu
can be used. The machine offers a data bank in which 14 sets of data can be stored.

If you want to switch to a particular product, select one of the product numbers by pressing
NEXT or PRIOR and confirm with ENTER .The new parameters are valid now.

After switching to a new product bank the machine assumes the label roll has been changed or
that a parameter such as STOD is different and so requires an initialisation of the label position
at the dispensing edge. This is done by pressing the FEED key after loading a new product
bank at which time the machine will move the first detected label edge to the dispense position.

Note: If the FEED key is not pressed after loading a new product bank the first
detected label edge will be moved to the dispense position at the first signal from
the product sensor!

Note: The function FACT available in the configuration menu clears all the product
banks.