Dispenser adjustment

Label position ____________________________________________________POS

Function: The start position

POS defines when the labelling should take place, after the product

has passed the product sensor. Changing the value for POS changes the applied label position
on the product.
Only available if no applicator is used.
Range: up to 999.9 mm in steps of 0.1 mm.

Start delay ______________________________________________________STAD

Function: Delay time for the dispensing after the product has passed the product sensor. This
value influences the position of the label on the product.
Only available if an applicator is used.
Range: 1 to 9999 ms

Stop position ___________________________________________________ STOD

Function: Stop position of the label once the label edge has reached the dispensing edge. The
STOD value defines the actual stop position of the label in steps of 0.1 mm.

With this adjustment the label can be made to stop directly at the dispensing edge. To make
the label stop after the dispensing edge the value of STOD should be adjusted accordingly.

y

Select the parameter

STOD by pressing the keys FUNCTION.

y

By pressing the key ENTER the data input is activated.

Range: 0.0 .... 200.0 (mm).

Labelling time___________________________________________________ BLOW

Function: The labelling time defines how long the applicator should blow the label onto the
product.
Only available if an applicator is used. BLOW is identical with APT2
Range: 1 to 9999 ms

Dispensing speed ________________________________________________VELO

Function: This parameter defines the speed for the label material. Only available if no applicator
is used: With an automatic product speed sensor the actual speed is shown.
Range :

0.2 ... 30.0 m/min