Alx 720 – Avery Dennison ALX 720 User Manual
Page 83

Operators Manual
ALX 720
4/09
Page 83
Remote programming
Command Description
Range
#!MACHnnnn
Machine type
0000 ALS230
0001 ALX720
0002 ALS330
0003 ALS430
#!MDIRnnnn
Motor direction
0000 Right --- >
0001 Left < ---
#!MLABnnnn
Missing label error
0000 NONE
0001 Warning
0002 Error 1
0003 Error 2
#!PDT nnnn
Print dwell time
0001 – 1000 ms
0000 printer off
#!PHT nnnn
Printer hold time
0001 – 7500 ms
#!POS_nnn Labelling
position
0001 – 9999 * 0.1 mm
#!PRDLnnnn Product
length
0005 – 4000 mm
#!P_S_nnnn
Polarity product sensor
0000 LEDG
0001 TEDG
#!RAMPnnnn
Acceleration Ramp
0000 NORM
0001 FAST
#!SLEWnnnn
Slew speed
0000 = FAST
0001 = SLOW
#!STADnnnn Start
delay
0001 - 9999 ms
#!STODnnnn Stop
position
0080 - 9999 * 0.1 mm
#!VELOnnnn Speed
0020 - 0300 * 0.1m/min
#!SAVEnnnn
Store in data bank
0001 - 0009
#!LOADnnnn
Load data bank
0001 - 0009
The following commands do not have parameter values. With these commands the host can
monitor and control the machine.
#!CLRC
Set label counter to 0
#!CLRE
Clear error message
#!CLRW Clear
warning
#!ERRF
The machine sends an error status to the monitoring computer. The message
ERR8___4__1_<04H> means, error 8, 4 and 1 have occurred.
#!WARF
The machine sends a warning status to the monitoring computer. The message
WARF7______0 means: The warnings 7 and 0 have occurred.
#!LABC
The machine sends the number of dispensed labels e.g. LABC0000008359 back