beautypg.com

Alx 720 – Avery Dennison ALX 720 User Manual

Page 83

background image

Operators Manual

ALX 720

4/09

Page 83

Remote programming

Command Description

Range

#!MACHnnnn

Machine type

0000 ALS230
0001 ALX720
0002 ALS330
0003 ALS430

#!MDIRnnnn

Motor direction

0000 Right --- >
0001 Left < ---

#!MLABnnnn

Missing label error

0000 NONE
0001 Warning
0002 Error 1
0003 Error 2

#!PDT nnnn

Print dwell time

0001 – 1000 ms
0000 printer off

#!PHT nnnn

Printer hold time

0001 – 7500 ms

#!POS_nnn Labelling

position

0001 – 9999 * 0.1 mm

#!PRDLnnnn Product

length

0005 – 4000 mm

#!P_S_nnnn

Polarity product sensor

0000 LEDG
0001 TEDG

#!RAMPnnnn

Acceleration Ramp

0000 NORM
0001 FAST

#!SLEWnnnn

Slew speed

0000 = FAST
0001 = SLOW

#!STADnnnn Start

delay

0001 - 9999 ms

#!STODnnnn Stop

position

0080 - 9999 * 0.1 mm

#!VELOnnnn Speed

0020 - 0300 * 0.1m/min

#!SAVEnnnn

Store in data bank

0001 - 0009

#!LOADnnnn

Load data bank

0001 - 0009


The following commands do not have parameter values. With these commands the host can
monitor and control the machine.

#!CLRC

Set label counter to 0


#!CLRE

Clear error message


#!CLRW Clear

warning


#!ERRF

The machine sends an error status to the monitoring computer. The message
ERR8___4__1_<04H> means, error 8, 4 and 1 have occurred.


#!WARF

The machine sends a warning status to the monitoring computer. The message
WARF7______0 means: The warnings 7 and 0 have occurred.


#!LABC

The machine sends the number of dispensed labels e.g. LABC0000008359 back