Operation

4.4 Control of dispense unit

4.4.1 Dispenser

Menu

selection

Turning on the mains switch and at the same time pressing one of the panel keys, you may
select between several options:

PANEL KEY
& mains switch

Function Display

message

FEED Material

initialisation

INIT

NEXT FUNCTION

Standard menu

ON

PRIOR FUNCTION

Product menu

PD0n

ENTER Configuration

menu

CODE


Press the key as long as the display shows the version number. One of the above mentioned
messages appears in the display. Calling the product menu is only possible, if at least one
product bank has been programmed.
If you do not press a panel key while turning on the machine the same menu is active that has
been used

before the machine was switched off.

4.4.2 Missing label function and web breaks

The missing label function stops the label web in the correct position even when a label is
missing from the label web. If there are more than 3 missing labels from the web then the
machine will stop and give the correct message E_1.
If the label web has broken or come to an end then the machine will no longer be able to find
the next leading label edge and so after more than 3 signals from the product sensor the error
message E_1 will also be generated.

4.4.3 Display and data input

The operation of the machine is controlled by the operator panel. Data can be displayed and
changed. The displays have different meanings:

y

Parameter selection:

In the display a parameter is shown, e.g. POS, STAD, or PD02 (product menu no. 02).
By pressing the keys FUNCTION another parameter can be selected. By pressing the
key ENTER the data is displayed.

y

Data display:

The display shows the values of the parameters (e.g. 0123) or possible adjustments
e.g. (AUTO). The data value is changed by pressing the FUNCTION keys. By pressing
the key ENTER the data input is completed and a new parameter is shown.