beautypg.com

Od control sensor, Alx 720, Operators manual – Avery Dennison ALX 720 User Manual

Page 106: 2 od control sensor

background image

Operators Manual

ALX 720

4/09

Page 106

Connections and signals

10.3.2 OD Control sensor

Optional an OD control could be mounted to control the label roll. If the label material is nearly
empty the sensor gives an signal. A warning message and an output signal inform the personal
that in the next time the material has to be changed.

+24V

GND

14

black

green

white
red

brown

5
9
4
8
3
7
2
6

1

Signal-

GND

Signal+

Supply

white

grey

blue

25

11
27

CN33

E3JK-R2M2

NPN sensor

5
9
4
8
3
7
2
6

1

Figure 25 NPN connection of optional ODC sensor

+24V

GND

14

black

green

white
red

25

11
27

CN33

brown

5
9
4
8
3
7
2
6

1

Signal-

GND

Signal+

Supply

white

grey

blue

S5-5-C8-30

PNP sensor

5
9
4
8
3
7
2
6

1

Figure 26 PNP connection of optional ODC sensor