Remote Programming

Sorensen SLM-Series DC Load

5-28

M540071-01 Rev C

The dynamic mode's Tlow or Thigh duration query command

Command Syntax:
SLM DC, SLD Modules: PERI:{LOW|HIGH}?{NL}

Description:
PERI:LOW? returns the presently programmed low duration time in dynamic load mode
PERI:HIGH? returns the presently programmed high duration time in dynamic load mode
The engineering unit is “msec”.

RISE Time

Purpose:
The dynamic load mode's RISE slew rate query command

Command Syntax:
SLM DC Modules:

RISE?{NL}

Description:
RISE? returns the presently programmed low load current level in Constant Current mode
The engineering unit is “A/us”.

FALL Time

Purpose:

The dynamic load mode's FALL slew rate query command.

Command Syntax:
SLM DC Modules:

FALL?{NL}

Description:
FALL? returns the presently programmed low load current level in Constant Current mode
The engineering unit is “A/us”.

SHORT ON/OFF

Purpose:
SHORt ON or OFF status query command.

Command Syntax:
All Modules:

SHOR?{NL}

Description:
SHOR? returns the presently SHORt status, “0” indicates SHORt OFF, and “1” indicates SHORt ON.

DYNAMIC ON/OFF

Purpose:
DYNamic ON or OFF status query command

Command Syntax:
SLM DC, SLD Modules: DYN?{NL}

Description:
DYN? returns the presently DYNamic ON or OFF status, “0” indicates static load mode or DYNamic
OFF, and “1” indicates DYNamic load mode or DYNamic ON.