Sorensen SLM-Series DC Load

Introduction, Features, Specifications

M540071-01 Rev C

1-5

CV

Mode:

In Constant Voltage mode, the load will attempt to sink enough current to maintain the
programmed voltage setting (see Figure 1-8).

I

V

LOAD
CURRENT

INPUT VOLTAGE

VOLTAGE
SETTING

Figure 1-8 Constant Voltage (CV) Mode

CP

Mode:

In Constant Power mode, the load will attempt to sink load power (load voltage x load current) in
accordance with the programmed power setting. (see Figure 1-9).

V

0

I

P O W E R

S E T T I N G

Figure 1-9 Constant Power (CP) Mode

Wide-Range Dynamic Load

The Dynamic load can simulate real-world load conditions, thereby providing relevant testing
and evaluation for the power source products. Dynamic loading is available for CC (Constant
Current) and CP (Constant Power) modes.