beautypg.com

AMETEK SLM Series RevC User Manual

Page 43

background image

Sorensen SLM-Series DC Load

Operation

M540071-01 Rev C

3-15

Normal Operating Mode Flowchart

MODE

Press MODE

Button until

desired mode is

illuminated CC,

CR, CV, CP

PRES

LOW

HIGH

DYN/STA

LEVEL

SHORT

LOAD

T

HIGH

T

LOW

FALL

RISE

Dynamic

Shorts MODE?

YES

NO

If only one value is

desired, set HIGH

to maximum rated

value. Use LOW

to set desire value.

×Ø

↑↓

Coarse/fine setting

CR or CV

Mode?

PRES

YES

YES

NO

YES

LOAD

×Ø

↑↓

Coarse/fine setting

×Ø

↑↓

Coarse/fine setting

×Ø

↑↓

Coarse/fine setting

×Ø

↑↓

Coarse/fine setting

×Ø

↑↓

Coarse/fine setting

Toggle PRESet

viewing off (LED

off or green)

Toggle between

HIGH (amber

LED) and LOW

(LED off)

Toggle between

HIGH (amber

LED) and LOW

(LED off)

Turn load off

(LED off)

Toggle dynamic

mode (LED on)

and static mode

(LED off)

Normal Operating

Modes

Figure 3-5 Normal Operating Mode Flowchart