beautypg.com

AMETEK SLM Series RevC User Manual

Page 77

background image

Sorensen SLM-Series DC Load

Remote Programming

M540071-01 Rev C

5-21

CV:HIGH? return the presently programmed high load voltage level in Constant Voltage mode of
SLM DC electronic load module.
The engineering unit is "V".

POWER Level

The Constant Power mode's load power level query command.
Command Syntax:
SLM DC Modules:

CP:{LOW|HIGH}?{NL}

Description:

CP:LOW? return the presently programmed low load power level in Constant Power mode of SLM
DC electronic load module.
CP:HIGH? return the presently programmed high load power level in Constant Power mode of SLM
DC electronic load module.
The engineering unit is "W".

LOAD ON/OFF

Purpose:
LOAD ON or LOAD OFF status query command.

Command Syntax:
All Modules:

LOAD?{NL}

Description:
LOAD? returns the present load status, “0” indicates LOAD OFF, and “1” indicates LOAD ON.

LOAD ON Voltage

Purpose:
LOAD ON voltage level query command.

Command Syntax:
SLM DC, SLD Modules: LDON?{;|NL}

Description:
LDON? returns the present load on voltage of SLD-series electronic load module.

LOAD OFF Voltage

Purpose:
LOAD OFF voltage level query command.

Command Syntax:
SLM DC, SLD Modules: LDOF?{;|NL}

Description:
LDOF? returns the present load off voltage of SLD-series electronic load module.

LEVEL HIGH/LOW

Purpose:
Static mode's LEVEL low or high status query command or active LEVEL of AC electronic load
query command.

Command Syntax:

SLM Modules:

LEVE?{NL}