AMETEK SLM Series RevC User Manual
Page 61

Sorensen SLM-Series DC Load
Remote Programming
M540071-01 Rev C
5-5
STATE Command
Model
RETURN
SLM DC
SLD
SLM AC
[STATe:] LOAD{SP}{ON|OFF}{;|NL}
•
•
•
[STATe:] LOAD{?}{;|NL}
•
•
•
0=OFF, 1=ON::
[STATe:] MODE{SP}{CC|CR|CV|CP}{;|NL}
•
•
•
[STATe:] MODE{?}{;|NL}
•
•
•
0=:CC, 1=:CR
2=:CV, 3=:CP
[STATe:] SHORt{SP}{ON|OFF}{;|NL}
•
•
•
[STATe:] SHORt{?}{;|NL}
•
•
•
0=OFF, 1=ON::
[STATe:] PRESet{SP}{ON|OFF}{;|NL}
•
•
•
[STATe:] PRESe{?}{;|NL}
•
•
•
0=OFF, 1=ON::
[STATe:] SENSe{SP}{ON|OFF}{;|NL}
•
•
•
[STATe:] SENSe{?}{;|NL}
•
•
0=OFF, 1=ON::
[STATe:] LEVEl{SP}{HIG|LOW|AIB}{;|NL}
•
•
[STATe:] LEVEl{?}{;|NL}
•
•
0:=LOW,
1:=HIGH
[STATe:] RANGe?{;|NL}
1=AUTO,
2=Fixed Range II
[STATe:] DYNamic{SP}{ON|OFF}{;|NL}
•
•
[STATe:] DYNamic{?}{;|NL}
•
•
0=:OFF, 1:=ON
[STATe:] SYNCronize{SP}{ON|OFF}{;|NL}
•
[STATe:] SYNCronize{?}{;|NL}
•
0=OFF, 1=ON::
[STATe:] WATT{SP}{ON|OFF}{;|NL}
•
•
[STATe:] WATT{?}{;|NL}
•
•
0=OFF, 1=ON::
[STATe:] CLEar{;|NL}
•
•
•
[STATe:] ERRor{?}{;|NL}
•
•
•
Dddddddd
[STATe:] DUAL{SP}{DVM|DAM|OFF}{;|NL}
•
[STATe:] PARAllel{SP}{ON|OFF}{;|NL}
•
[STATe:] NGAB{SP}{ON|OFF}{;|NL}
•
0:=OK, 1=:NG
[STATe:] NGAB{?}{;|NL}
•
0:=OK, 1:=NG
[STATe:] NG{?}{;|NL}
•
•
•
0:=OK, 1:=NG
[STATe:] PROTect{?}{;|NL}
•
•
•
Dddddddd
Table 5-4 State Command Summary