beautypg.com

AMETEK SLM Series RevC User Manual

Page 83

background image

Sorensen SLM-Series DC Load

Remote Programming

M540071-01 Rev C

5-27

CURRENT Limit

Purpose:
To read the set value of upper/lower limit value of threshold current.

Command Syntax:
All Modules:

LIM:CURR{HIGH|LOW}?{;|NL}

Description:
LIM:CURR:LOW? Reads back the lower limit set value of threshold current; unit is
“amps (A)”.

POWER Limit

Purpose:

To read the set value of upper/lower limit value of threshold power(W).

Command Syntax:
SLM DC Modules:

LIM:POW{HIGH|LOW}?{;|NL}

Description:

LIM:POW:LOW? Reads back the lower limit set value of threshold power; unit is “watts” (W).

VA Limit

Purpose:
To read the set value of upper/lower limit value of threshold power (VA).

Command Syntax:
SLM AC Modules:

LIM:VA{HIGH|LOW}?{;|NL}

Description:
LIM:VA:LOW? Reads back the lower limit set value of threshold power, unit is (VA).

NG

Purpose:
To read the set value of NG.

Command Syntax:
All Modules:

NG?{;|NL}

Description:
NG? Reads back the condition indicating light of NG. “0” denotes that NG (NO GOOD) indicating
light has been extinguished. “1” denotes that NG indicating light has been lit.

NG Enable /Disable

Purpose:
To read NG ON/OFF setting.

Command Syntax:
SLD Modules:

NGAB{?}{;|NL}

Description:
NGAB? returns the presently NG ON/OFF status, “0” indicates NG disable, and “1” indicates NG
enable.

PERIOD

Purpose: