AMETEK SLM Series RevC User Manual
Page 78

Remote Programming
Sorensen SLM-Series DC Load
5-22
M540071-01 Rev C
Description:
LEVE? returns the present level status, “0” indicates LEVEl LOW, and “1” indicates LEVEl HIGH.
PRESET ON/OFF
Purpose:
PRESet ON or OFF status query command.
Command Syntax:
All Modules:
PRES?{NL}
Description:
PRES? returns the present preset status, “0” indicates PRESet OFF, and “1” indicates PRESet ON.
MODE
Purpose:
CC, CR, CV or CP operating mode query command.
Command Syntax:
All Modules:
MODE?{NL}
Description:
MODE? returns the present operating mode status, ”0” indicates CC MODE, ”1” indicates CR
MODE, and “2” indicates CV MODE, “3” indicates CP MODE.
CV MODE is available DC electronic loads (except 500V models).
CP MODE is available in SLM DC electronic load modules.
NAME
Purpose:
Electronic Load module model number query command.
Command Syntax:
All Modules:
NAME?{NL}
Description:
NAME? return the active Electronic Load channel's model number.
PROTECTION Status Register
Purpose:
OPP, OTP, OVP, and OCP protection status query command.
Command Syntax:
All Modules:
PROT?{NL}
Description:
PROT? returns the present protection status; the status byte register summarizes all of the
protection status events from all status register. the following figure describes the status byte the
happened on the SLM-series Electronic load. The PROT status byte register is cleared when a
CLER command clears all of the PROT and ERR status registers.