beautypg.com

2 alarm input port, 3 alarm output port, Alarm input port – AGI Security SYS-HC0451 HDCVI DVR User Manual User Manual

Page 59: Alarm output port

background image

HDCVI Standalone DVR User’s Manual

50

R+ R-: input wire

3.6.2 Alarm Input Port

Please refer to the following sheet for more information.
 Grounding alarm inputs. Normal open or Normal close type)
 Please parallel connect COM end and GND end of the alarm detector (Provide

external power to the alarm detector).

 Please parallel connect the Ground of the DVR and the ground of the alarm detector.
 Please connect the NC port of the alarm sensor to the DVR alarm input(ALARM)
 Use the same ground with that of DVR if you use external power to the alarm device.

Figure 3-2

3.6.3 Alarm Output Port

 Provide external power to external alarm device.
 To avoid overloading, please read the following relay parameters sheet carefully.
 RS485 A/B cable is for the A/B cable of the PTZ decoder.

T+,T-,R+,R- are four-wire double duplex RS485 port.

T+ T-: output wire

R+ R-: input wire

Relay Specification

Model:

JRC-27F

Material of the

touch

Silver

Rating
(Resistance

Load)

Rated switch capacity

30VDC 2A, 125VAC 1A

Maximum switch power

125VA 160W

Maximum switch voltage

250VAC, 220VDC

Maximum switch currency

1A

Insulation

Between touches with same

polarity

1000VAC 1minute

Between touches with different

polarity

1000VAC 1minute

Between touch and winding

1000VAC 1minute

This manual is related to the following products: