beautypg.com

D*ap8 – Junger Audio D*AP8 Digital Audio Processor User Manual

Page 86

background image

D*AP8

84


Setup GUI – EVENTS – Actions – Bypass Actions

The bypass action is bound to the button of the X*AP RM

1

remote panel.

You must simply select "follow" or "-" in the setup field.

But it also allows you to turn the bypass on for, some or all function blocks by simply enabling the check
boxes in the right hand panel:

Triggered Bypass


Trigger

Source

The X*AP RM1 button is the trigger source

Lock Source

[ON / OFF]

The X*AP RM

1

remote panel button may be

disabled / enabled here.

Force Trigger Active

[ON / OFF]

Force the bypass function from the GUI instead of the
X*AP RM

1

remote panel button.

Bypass Event

[4 x 2 / 5.1 + 2]

Programs

[Input / Upmix / Filter – Spectral Signature / Filter – Equalizer /
Dynamics – Compressor / Voice Over / Level Magic – Leveler /
Level Magic –Limiter / Output]

AUX

[Input]

Manual Bypass

You can use the check boxes for manually bypassing the respective
function block of that program.

This manual is related to the following products: