beautypg.com

D*ap8, Operating manual – Junger Audio D*AP8 Digital Audio Processor User Manual

Page 2

background image

DAP8-MEI_manual_EN_150713.doc

D*AP8


Hardware features

D*AP8

1RU / 19" generic compact 8 channel processing unit

X*AP RM

1

optional 1RU remote panel

Dolby decoder

optional built in Dolby D/D+/E decoder incl. metadata emulation

Dolby encoder

optional built in Dolby D/D+/AAC/HE-AAC or Dolby E encoder

Dolby metadata I/O

two 9-pin D-Sub connectors (RS485)

4x AES (BNC) I/O + SRC

on board AES I/Os with relay bypass and (selectable) SRC per input

Two interface slots

expansion slots for optional I/O boards:

3-G/HD/SD-SDI, MADI, Dante, 4x AES I/O, 4Ch Analog I/O,
8 Ch Analog Out

RJ45 network connector

100BaseT full duplex Ethernet interface

USB connector

built in USB < > serial adapter to access the service port

8x GPI/O

balanced inputs and SSR contacts on a 25pin Sub-D

Aux power supply

isolated 5V supply for external GPI/O wiring

External sync IN

BNC input (Word Clock, AES, Black Burst, Tri-Level)

Sync OUT

BNC Word Clock output


Software features of D*AP8


TP limiter

Junger Audio true peak limiter control algorithm

• LevelMagic II™

optional loudness management according to ITU BS.1770-1/-2/-3

EBU R128, ATSC A/85, ARIB TR-B32, Free TV OP-59,
Portaria 354

• Dynamic filter / EQ

optional SPECTRAL SIGNATURE™ dynamic filter and

5 band parametric EQ

Dynamics

optional compressor, expander / gate

• Fail over Upmix

optional automatic fail over / optional 5.1 Upmix

• Voice over

optional 5.1 or stereo voice over from program input

• FM Conditioner

optional MPX limiter and Pre-Emphasis limiter

• Dolby metadata emulation

optional Dolby metadata emulation

• Dolby metadata generator

generates RDD6 complied metadata

• Loudness measurement

in reference to the respective standard

SNMP agent

SNMP v1, see D*AP8-MIB

• Remote control

X*AP RM1 remote panel, l-s-b EmBER plus protocol and legacy GPI/Os

operating manual

This manual is related to the following products: