D*ap8, Operating manual – Junger Audio D*AP8 Digital Audio Processor User Manual
Page 2

DAP8-MEI_manual_EN_150713.doc
D*AP8
Hardware features
•
D*AP8
1RU / 19" generic compact 8 channel processing unit
•
X*AP RM
1
optional 1RU remote panel
•
Dolby decoder
optional built in Dolby D/D+/E decoder incl. metadata emulation
• Dolby encoder
optional built in Dolby D/D+/AAC/HE-AAC or Dolby E encoder
• Dolby metadata I/O
two 9-pin D-Sub connectors (RS485)
•
4x AES (BNC) I/O + SRC
on board AES I/Os with relay bypass and (selectable) SRC per input
• Two interface slots
expansion slots for optional I/O boards:
3-G/HD/SD-SDI, MADI, Dante, 4x AES I/O, 4Ch Analog I/O,
8 Ch Analog Out
• RJ45 network connector
100BaseT full duplex Ethernet interface
• USB connector
built in USB < > serial adapter to access the service port
• 8x GPI/O
balanced inputs and SSR contacts on a 25pin Sub-D
•
Aux power supply
isolated 5V supply for external GPI/O wiring
•
External sync IN
BNC input (Word Clock, AES, Black Burst, Tri-Level)
•
Sync OUT
BNC Word Clock output
Software features of D*AP8
•
TP limiter
Junger Audio true peak limiter control algorithm
• LevelMagic II™
optional loudness management according to ITU BS.1770-1/-2/-3
EBU R128, ATSC A/85, ARIB TR-B32, Free TV OP-59,
Portaria 354
• Dynamic filter / EQ
optional SPECTRAL SIGNATURE™ dynamic filter and
5 band parametric EQ
•
Dynamics
optional compressor, expander / gate
• Fail over Upmix
optional automatic fail over / optional 5.1 Upmix
• Voice over
optional 5.1 or stereo voice over from program input
• FM Conditioner
optional MPX limiter and Pre-Emphasis limiter
• Dolby metadata emulation
optional Dolby metadata emulation
• Dolby metadata generator
generates RDD6 complied metadata
• Loudness measurement
in reference to the respective standard
•
SNMP agent
SNMP v1, see D*AP8-MIB
• Remote control
X*AP RM1 remote panel, l-s-b EmBER plus protocol and legacy GPI/Os
operating manual