D*ap8 – Junger Audio D*AP8 Digital Audio Processor User Manual
Page 6

D*AP8
4
Hardware concept
The D*AP8 editions are based on the D*AP8 device that carries all relevant connectors.
An optional X*AP RM
1
remote panel can be used to control the D*AP8.
D*AP8 front panel view
The front panel of the D*AP8 has a 3 line status display and two hidden touch buttons ~ 2.5cm left of the
display. Button 1 = Home will switch back to the power up display no matter which display level you are in.
Button 2 controls the multi level display:
Level 1
Power up display [Device type, firmware version]
Level 2
Status [OK / Error] / Device Name / IP address
Level 3
IN peak meter (10x)
Level 4
OUT peak meter (10x)
The total number of display levels depends on the number of programs. For 5.1 + 2 mode (2 programs) we
will have 4 more levels while for 4 x 2 (4 programs) we will have 8 more levels:
Level 5 - 8
Program 1 - 4 Out - short term loudness
Level 9 - 12
Program 1 - 4 Out - integrated loudness and integration time
The measures of the loudness displays depend on the setup of the respective loudness mode
(see AUDIO PROCESSOR > SETUP > Loudness Mode).
Display background
Green = device status OK
color
Red
= device status ERROR
X*AP RM
1
front panel view
The X*AP RM
1
remote panel is powered by POE (Power Over Ethernet) or an external wall plug PS and
designed to control multiple D*AP8 units one at a time. For details of operation see extra manual
"XAP_manual_EN_140328.pdf" or later.