The
reset_n
signal resets the control logic and state machines that control the FIR
Compiler (not including data storage elements that hold previous inputs used to
calculate the result).
The previous data is not cleared when the
reset_n
signal is applied. To clear the
data, set the
ast_sink_data
port to
0
for n clock cycles, where n = (number of
coefficients) × (number of input channels) × (number of clock cycles needed to compute a FIR
result).
The FIR output value depends on the coefficient values in the design. Therefore, the
timing diagrams of your own design may be different than those shown in the
following figures. However, you can use the testbench generated by the FIR compiler
to get the correct timing relation between signals for a specific parameterized case.
All timing diagrams assume a full streaming operation where
ast_source_ready
and
ast_sink_ready
are always
1
(unless otherwise stated).
ast_source_channel
Output
Indicates the index of the channel whose result is presented at the data output.
The width of this signal = log
2
(number of channels).
ast_source_data
Output
Filter output. The data width depends on the parameter settings.
ast_source_sop
Output
Marks the start of the outgoing FIR filter result group. If '1', a result
corresponding to channel 0 is output.
ast_source_eop
Output
Marks the end of the outgoing FIR filter result group. If '1', a result corresponding
to channel N-1 is output, where N is the number of channels.
ast_source_error
Output
Error signal indicating Avalon-ST protocol violations on the source side:
■
00: No error
■
01: Missing SOP
■
10: Missing EOP
■
11: Unexpected EOP
Other types of errors are also marked as 11.
coef_set
Input
Selects which coefficient set the FIR filter uses for the calculation. (Appears when
multiple coefficient sets are used.) The width of this signal = log
2
(number of
coefficient sets).
coef_in_clk
Input
Clock to reload coefficients when coefficients are stored in memory. (Appears
when the Coefficient Reload option is selected and the Use Single Clock option is
not selected) This clock can be different than
clk
.
coef_set_in
Input
Selects which coefficient set to be reloaded. (Appears when multiple coefficient
sets are used and the Coefficient Reload option is selected.) The width of this
signal = log
2
(number of coefficient sets)
coef_in
Input
Input coefficient value when reloading coefficient. (Appears when the Coefficient
Reload option is selected)
coef_we
Input
Active high write enable signal. Enables coefficient overwriting when coefficients
are reloadable.
coef_ld
Output
Coefficient reload control port. This port is created only when multicycle filters are
selected and the coefficient storage is logic cells.