To activate and configure averaging:
1.
From the Settings menu, select Acquisition.

2. Under the Analysis tab, set the averaging parameters.

Select Use averaging to activate it (not selected by default).

Select the number of bursts to average on (1 to 64, or Infinite).

Set the averaging window (1 to 10 ps, default = 1 ps).

3. Click Apply to confirm your settings, or OK to also close the window.

Applying Advanced Signal Processing

Algorithms

You can activate or deactivate specific signal processing algorithms before
or while acquiring data, or afterwards in reanalysis mode (see Reanalyzing
Acquisitions with New Settings
on page 115). Th
e following algorithms are
available, depending on the selected modulation format and input pattern:

Polarization Demultiplexing

For details, see Polarization Demultiplexing on page 245.

Intermediate Frequency Recovery

For details, see Intermediate Frequency (IF) Recovery on page 246.