:CALCulate[1..n]:RBW:INSTrument

Description

This command sets whether the application uses

the Instrument RBW or the user defined RBW

value.

For this command to be accepted, the OSA

module must be in Ready state with no

acquisition in progress.

At *RST, this value is 1 (or ON).

Syntax

:CALCulate[1..n]:RBW:INSTrument

wInstrumentState>

Parameter(s)

RbwInstrumentState:
The program data syntax for

is defined as a

element. The

special forms ON and

OFF are accepted on input for increased

readability. ON corresponds to 1 and OFF

corresponds to 0.

The special forms ON
and OFF are accepted on input for increased

readability. ON corresponds to 1 and OFF

corresponds to 0.