Managing Results

380

FTB-5240S/5240BP

Managing EDFA Test Results

2. Select a row from the Results tab to view the channel results for the

selected channel.

3. Under Results pane, you can view the following results:

³

Channel name: indicates the channel name as defined in the
channel list.

³

Channel Center (nm or THz): indicates the central
wavelength/frequency for the channel.

³

Input signal power (dBm): indicates the input signal power for
the selected channel (excludes noise).

³

Output signal power (dBm): indicates the output signal power for
the selected channel (excludes noise).

³

Gain: indicates the gain (Output Signal Power - Input Signal Power)
for the selected channel.

³

Gain - Avg. Gain: indicates the selected channel gain minus the
average of all channel gains.