Summary of keyboard commands – Delta MMC120 User Manual
Page 81
MMC120 Linear Motion Control Module
Appendix A: DCS120
Delta Computer Systems, Inc. 360/254-8688
81
Summary of Keyboard Commands
When the Shift, Ctrl or Alt keys are pressed, a menu of the available commands is displayed at the bottom of the screen.
Pressing the key multiple times will scroll through the entire list of commands available with that key.
To change most parameters, cursor to the field and enter a new value. To see the help file of a parameter, press Ctrl-H
when the cursor is on that field. To enter hex numbers, type a "0" (the number zero) as the left-most digit of the
number. After typing the desired new value, DCS120 will accept the input a soon as you hit Enter or move the cursor
to a new location.
NOTE: New values are not automatically transferred to the Motion Control Module. An Alt-P command must be issued to
transfer initialization parameters.
On color monitors the initialization parameters are displayed in gray to indicate parameters have not been transferred.
Use an Alt-P command on each axis to transfer the parameters to the Motion Control Module. (The screen display of
the parameters changes from gray to white after an Alt-P is issued.)
SHIFT Key Commands
SHIFT
?
Display full help information using text editor
Ctrl Key Commands
Ctrl
B
Display Status bits in expanded format (Toggle)
C
View configuration
D
Temporary exit to DOS; return to DCS120 by typing EXIT
E
Edit .INI configuration file (TE editor is included as default)
F
Enter table editor for Function keys (F1-F10)
H
Context-sensitive help
P
Enter table editor for profiles
Q
Quit DCS120
S
Enter Event Control editor
T
Toggle between Write mode and Readback mode
V
View datalog raw data (after graph taken)
F1-F10
Executes Command saved for function key. Uses all 6 command parameters stored: MODE,
ACCEL, DECEL, SPEED, COMMAND VALUE, and COMMAND
Function Keys
F1-F10
Executes command stored for function key. Uses only COMMAND VALUE and COMMAND
parameters
Command Line
P0 Pos 0 Cnt 0
P1 Pos 1 Cnt 1
Scale and Offset field calculation. Place cursor on axis of interest. See page 82 for more
information.
R filename
Reads the project parameters for current motion controller module
S filename
Saves current setup using the filename.BDn where n represents current module location; execute
for each controller module. Do not enter the .BDn extension.
RP filename
Displays graph previously saved using SP command
SP filename
Saves current graph in a plot file specified by filename. Do not enter the .plt extension.
SQ filename
Saves Command Queue to .log file specified by filename. Do not enter the .log extension.
T n
Sets the plot timebase to n milliseconds
PTn
Sets the type of the extra plot information. n can be one of the following:
0
Extra precision positions
1
Command and Command Value
2
Event Step and Link Value
3
Raw Transducer Counts