Delta MMC120 User Manual
Page 61
MMC120 Linear Motion Control Module
Communicating with the MMC120
Delta Computer Systems, Inc. 360/254-8688
61
Second Scan:
Returns:
3TTTTT
+ 0
xxxx
(Axis 1 status)
+ 1
xxxx
+ 2
xxxx
(Axis 2 Status)
+ 3
0002d (Profile 5 MODE)
Sends:
4TTTTT
+ 0
xxxx
+ 1
xxxx
+ 2
00A5h (Get Profile 5 ACCEL)
+ 3
xxxx
Third Scan:
Returns:
3TTTTT
+ 0
xxxx
(Axis 1 status)
+ 1
xxxx
+ 2
xxxx
(Axis 2 status)
+ 3
0050d (Profile 5 ACCEL)
Sends:
4TTTTT
+ 0
xxxx
+ 1
xxxx
+ 2
00A6h (Get Profile 5 DECEL)
+ 3
xxxx
Fourth Scan:
Returns:
3TTTTT
+ 0
xxxx
(Axis 1 status)
+ 1
xxxx
+ 2
xxxx
(Axis 2 status)
+ 3
0035d (Profile 5 DECEL)
Sends:
4TTTTT
+ 0
xxxx
+ 1
xxxx
+ 2
00A7h (Get Profile 5 SPEED)
+ 3
xxxx
Fifth Scan:
Returns:
3TTTTT
+ 0
xxxx
(Axis 1 status)
+ 1
xxxx
+ 2
xxxx
(Axis 2 status)
+ 3
8000d (Profile 5 SPEED)
When this command is used, the MMC120 ignores the SAR field and the parameter register.