Status word bit map – Delta MMC120 User Manual
Page 45
MMC120 Linear Motion Control Module
Motion Control Parameters
Delta Computer Systems, Inc. 360/254-8688
45
STATUS Word Bit Map
The axis Status word contains 16 bits of information about the status of the axis. This hexadecimal table
provides an easy way to convert hexadecimal numbers to bit patterns.
F
1 1 1 1
1 1 1 1
1 1 1 1
1 1 1 1
E
1 1 1 0
1 1 1 0
1 1 1 0
1 1 1 0
Hexadecimal To
D
1 1 0 1
1 1 0 1
1 1 0 1
1 1 0 1
Binary Conversion
C
1 1 0 0
1 1 0 0
1 1 0 0
1 1 0 0
Table
B
1 0 1 1
1 0 1 1
1 0 1 1
1 0 1 1
A
1 0 1 0
1 0 1 0
1 0 1 0
1 0 1 0
9
1 0 0 1
1 0 0 1
1 0 0 1
1 0 0 1
8
1 0 0 0
1 0 0 0
1 0 0 0
1 0 0 0
7
0 1 1 1
0 1 1 1
0 1 1 1
0 1 1 1
6
0 1 1 0
0 1 1 0
0 1 1 0
0 1 1 0
5
0 1 0 1
0 1 0 1
0 1 0 1
0 1 0 1
4
0 1 0 0
0 1 0 0
0 1 0 0
0 1 0 0
3
0 0 1 1
0 0 1 1
0 0 1 1
0 0 1 1
2
0 0 1 0
0 0 1 0
0 0 1 0
0 0 1 0
1
0 0 0 1
0 0 0 1
0 0 0 1
0 0 0 1
0
0 0 0 0
0 0 0 0
0 0 0 0
0 0 0 0
_______
_______
_______
_______
|*|*|*|*| |*|*|*|*| | | | | | | | | | |
|*|*|*| | | | | | | | |1|1|1| |1|1|1|1|
|1|2|3|4| |5|6|7|8| |9|0|1|2| |3|4|5|6|
Bit Definition
|_|_|_|_| |_|_|_|_| |_|_|_|_| |_|_|_|_|
--------------
/ / / /
/ / / /
/ / / /
/ / / /
**No Transducer ------------ 01 -/ / / /
/ / / /
/ / / /
/ / / /
**Transducer Noise --------- 02 --/ / /
/ / / /
/ / / /
/ / / /
**Transducer Overflow ------ 03 ---/ /
/ / / /
/ / / /
/ / / /
*Overdrive ---------------- 04 ----/
/ / / /
/ / / /
/ / / /
/ / / /
/ / / /
/ / / /
*Parameter Error ---------- 05 ------/ / / /
/ / / /
/ / / /
*Position Overflow -------- 06 -------/ / /
/ / / /
/ / / /
*Integrator Windup -------- 07 --------/ /
/ / / /
/ / / /
*Following Error ---------- 08 ---------/
/ / / /
/ / / /
/ / / /
/ / / /
Acknowledge -------------- 09 -----------/ / / /
/ / / /
Initialized -------------- 10 ------------/ / /
/ / / /
State B ------------------ 11 -------------/ /
/ / / /
State A ------------------ 12 --------------/
/ / / /
/ / / /
Open Loop ---------------- 13 ----------------/ / / /
Halt --------------------- 14 -----------------/ / /
Stopped ------------------ 15 ------------------/ /
In Position -------------- 16 -------------------/
* Can cause a Soft or Hard Stop if the corresponding bits are set in the AUTO STOP field.
** Will cause either a Soft or Hard Stop depending how AUTO STOP bits 9, 10, and 11 are set.