Communicating with the MMC120

MMC120 Linear Motion Control Module

64

Delta Computer Systems, Inc. 360/254-8688

Extended Command Type E - Event Step Transfer (1110 DSSS SSSS SNNN)

The "Event Step Transfer" commands are used to move event step information to and from the MMC120. The
‘D’ bit indicates the direction of data transfer (0 = Put Step, 1 = Get Step), the ‘S’ bits specify the step number,
and the ‘N’ bits specify the field of the step to be transferred. Commands E000 to E7FF put (write) data to the
MMC120, while commands E800 to EFFF get (read) data from the MMC120. While writing steps , the new
command value is echoed to the SAR.

To write event step information to the MM120 :

Cmd Reg 1

Parameter Register 1

E000

Step 0 MODE

E001

Step 0 ACCELERATION

E002

Step 0 DECELERATION

E003

Step 0 SPEED

E004

Step 0 COMMAND VALUE

E005

Step 0 COMMAND

E006

Step 0 LINK TYPE and LINK NEXT

E007

Step 0 LINK VALUE

E008

Step 1 MODE

E009

Step 1 ACCELERATION

.

.

.

.

E7FD

Step 255 COMMAND

E7FE

Step 255 LINK TYPE and LINK NEXT

E7FF

Step 255 LINK VALUE

To update two words every PLC scan, you can also use Command and Data Parameter Register 2 for axis 2.
By using Register 1 for the first half of a table and Register 2 for the second half, transfer time can be cut in
half.

To read event step information from the MMC120:

Cmd Reg 1

Status Word 1

E800

Step 0 MODE

E801

Step 0 ACCELERATION

E802

Step 0 DECELERATION

E803

Step 0 SPEED

E804

Step 0 COMMAND VALUE

E805

Step 0 COMMAND

E806

Step 0 LINK TYPE and LINK NEXT

E807

Step 0 LINK VALUE

E808

Step 1 MODE

E809

Step 1 ACCELERATION

.

.

.

.

EFFD

Step 255 COMMAND

EFFE

Step 255 LINK TYPE and LINK NEXT

EFFF

Step 255 LINK VALUE

The data will be valid when the ACK bit in the Status word toggles (on the next scan).