Extended Command Type E - Event Step Transfer (1110 DSSS SSSS SNNN)
The "Event Step Transfer" commands are used to move event step information to and from the MMC120. The
‘D’ bit indicates the direction of data transfer (0 = Put Step, 1 = Get Step), the ‘S’ bits specify the step number,
and the ‘N’ bits specify the field of the step to be transferred. Commands E000 to E7FF put (write) data to the
MMC120, while commands E800 to EFFF get (read) data from the MMC120. While writing steps , the new
command value is echoed to the SAR.
To write event step information to the MM120 :
Cmd Reg 1
Parameter Register 1
E000
Step 0 MODE
E001
Step 0 ACCELERATION
E002
Step 0 DECELERATION
E003
Step 0 SPEED
E004
Step 0 COMMAND VALUE
E005
Step 0 COMMAND
E006
Step 0 LINK TYPE and LINK NEXT
E007
Step 0 LINK VALUE
E008
Step 1 MODE
E009
Step 1 ACCELERATION
.
.
.
.
E7FD
Step 255 COMMAND
E7FE
Step 255 LINK TYPE and LINK NEXT
E7FF
Step 255 LINK VALUE
To update two words every PLC scan, you can also use Command and Data Parameter Register 2 for axis 2.
By using Register 1 for the first half of a table and Register 2 for the second half, transfer time can be cut in
half.
To read event step information from the MMC120:
Cmd Reg 1
Status Word 1
E800
Step 0 MODE
E801
Step 0 ACCELERATION
E802
Step 0 DECELERATION
E803
Step 0 SPEED
E804
Step 0 COMMAND VALUE
E805
Step 0 COMMAND
E806
Step 0 LINK TYPE and LINK NEXT
E807
Step 0 LINK VALUE
E808
Step 1 MODE
E809
Step 1 ACCELERATION
.
.
.
.
EFFD
Step 255 COMMAND
EFFE
Step 255 LINK TYPE and LINK NEXT
EFFF
Step 255 LINK VALUE
The data will be valid when the ACK bit in the Status word toggles (on the next scan).