beautypg.com

Specifications, Temperature, Humidity – Delta MMC120 User Manual

Page 11: Vibration resistance, Shock resistance, Esd immunity, Power requirements, Transducer inputs, Outputs, Isolation

background image

MMC120 Linear Motion Control Module

Overview

Delta Computer Systems, Inc. 360/254-8688

11

SPECIFICATIONS

Temperature

Operating:

0

o

C to +60

o

C

Storage:

-40

o

C to +85

o

C

Humidity

93% non-condensing

Vibration Resistance

1 g at 60 Hz to 500 Hz for 23 minutes

0.075 mm displacement from 10 Hz to 60 Hz

Shock Resistance

30 g for 11 milliseconds

ESD Immunity

8 kV

Power Requirements

+5V @ 1 Amp from the backplane

Transducer Inputs

Direct interface to magnetostrictive transducers

Differential or single-ended transducer compatibility

Start/Stop pulses or Pulse Width Modulated signals

Outputs

±10 volts into 2000 Ohm or greater load -- current output is available with the optional VC2100 voltage-to-
current converter

Isolation

All inputs and outputs used for control purposes are optically isolated from the module, with 2500VDC
withstand voltage

Each input and output section is isolated from the other sections

The RS-232 port is not isolated

I/O Protection

All inputs and outputs are protected against transients by clamp diodes

Agency Compliance

UL, CSA, and CE