background image

68

Operations

Trigger Out

PCIe-7360’s Application Function I/O (AFI) can be configured as
trigger output when receiving a software start command of digital
pattern acquisition or generation. The trigger out signal can syn-
chronize the operation between PCIe-7360 and DUT.

The pulse width of trigger out signal can be configured from 16ns
to 524.288 μs. (8 ns x (N+1), where N is from 1 to 65535

)

Figure 3-36: Configured AFI as Internal Software Trigger Output