Chapter 5 Parameters|VFD-S Series

Revision August 2006, SE08, SW V2.61

5-7

Pr. Explanation

Settings

Factory

Setting

NOTE

5-02

3rd Step Speed Freq.

d0.0 to d400 Hz

d0.0

5-03

4th Step Speed Freq.

d0.0 to d400 Hz

d0.0

5-04

5th Step Speed Freq.

d0.0 to d400 Hz

d0.0

5-05

6th Step Speed Freq.

d0.0 to d400 Hz

d0.0

5-06

7th Step Speed Freq.

d0.0 to d400 Hz

d0.0

5-07 PLC

Mode

d0: Disable PLC Operation
d1: Execute one program cycle
d2: Continuously execute program

cycles

d3: Execute one program cycle step

by step

d4: Continuously execute one

program cycle step by step

d5: Disable PLC operation, but can

set direction of 1st speed to 7th
speed

d0

5-08

PLC Forward/ Reverse Motion

d0 to d255 (0: FWD 1: REV)

d0

5-09

Time Duration of Zero Step Speed

d0 to d65500 Sec

d0

5-10

Time Duration of 1st Step Speed

d0 to d65500 Sec

d0

5-11

Time Duration of 2nd Step Speed

d0 to d65500 Sec

d0

5-12

Time Duration of 3rd Step Speed

d0 to d65500 Sec

d0

5-13

Time Duration of 4th Step Speed

d0 to d65500 Sec

d0

5-14

Time Duration of 5th Step Speed

d0 to d65500 Sec

d0

5-15

Time Duration of 6th Step Speed

d0 to d65500 Sec

d0

5-16

Time Duration of 7th Step Speed

d0 to d65500 Sec

d0

Group 6 Protection Parameters

Pr. Explanation

Settings

Factory

Setting

NOTE

6-00

Over-Voltage Stall Prevention

d0: Disable
d1: Enable

d1

115V/230V series: d350 to d410V

d390

6-01

Over-Voltage Stall Prevention Level

460V series: d700 to d820V

d780

6-02

Over-Current Stall Prevention Level

d20 to d150%

d130

d0: Disabled

d1: Enabled during constant speed

operation. After the over-torque
is detected, keep running until
OL1 or OL occurs.

d2: Enabled during constant speed

operation. After the over-torque
is detected, stop running.

d3: Enabled during running and

continues before Continuous
Output Time Limit (Pr.6-05) is
reached

6-03

Over-Torque Detection Mode

d4: Enabled during running. After

the over-torque is detected, stop
running.

d0

6-04

Over-Torque Detection Level

d30 to d200%

d150