beautypg.com

7 keypad display is abnormal, 8 phase loss (phl), 7 keypad display is abnormal -5 – Delta Electronics AC Motor Drive VFD007S23A User Manual

Page 142: 8 phase loss (phl) -5

background image

Chapter 7 Troubleshooting |VFD-S Series

Revision August 2006, SE08, SW V2.61

7-5

7.7 Keypad Display is Abnormal

Abnormal display or no display

Cycle power to AC motor drive

No

Yes

Yes

Yes

No

Display normal?

AC motor drive works normally

Fix connector and

eliminate noise

Check if all connectors are connect
correctly and no noise is present

AC motor drive has malfunction.
Please contact DELTA.

7.8 Phase Loss (PHL)

Phase loss

No

No

Yes

Yes

Check wiring at R, S and T terminals

Correct wiring

Check if the screws of terminals are tightened

No

Tighten all screws

Yes

Please check the wiring
and power system for
abnormal power

Maybe AC motor drive has malfunction or misoperation
due to noise. Please contact DELTA.

Check if the input voltage of R, S, T is unbalanced