beautypg.com

Delta Electronics AC Motor Drive VFD007S23A User Manual

Page 119

background image

Chapter 5 Parameters|VFD-S Series

5-64

Revision August 2006, SE08, SW V2.61

Terminal Unit). Users can select the desired mode along with the serial port

communication protocol in Pr. 9-04.

Code Description:

ASCII mode:

Each 8-bit data is the combination of two ASCII characters. For example, a 1-byte data:

64 Hex, shown as ‘64’ in ASCII, consists of ‘6’ (36Hex) and ‘4’ (34Hex).

Character ‘0’ ‘1’ ‘2’ ‘3’ ‘4’ ‘5’ ‘6’ ‘7’

ASCII

code 30H 31H 32H 33H 34H 35H 36H 37H

Character ‘8’ ‘9’ ‘A’ ‘B’ ‘C’ ‘D’ ‘E’ ‘F’

ASCII

code 38H 39H 41H 42H 43H 44H 45H 46H

RTU mode:

Each 8-bit data is the combination of two 4-bit hexadecimal characters. For example, 64

Hex.

2. Data Format

2.1 10-bit character frame (For 7-bit character):

( 7.N.2)

( 7.E.1)

Start
bit

0

1

2

3

4

5

6

Stop
bit

10-bit character frame

( 7.O.1)

Odd

parity

Start
bit

0

1

2

3

4

5

6

Stop
bit

10-bit character frame

Even

parity

Start
bit

0

1

2

3

4

5

6

Stop
bit

7-bit character

10-bit character frame

Stop
bit

7-bit character

7-bit character

2.2 11-bit character frame (For 8-bit character):