7.10 Motor Speed cannot be Changed

Motor can run but
cannot change speed

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

No

No

No

No

No

No

No

No

No

No

Check if the setting of the
max. frequency is too low

Check to see if frequency is
out of range (upper/lower)
boundaries

Modify the setting

Modify the setting

Yes

No

Yes

If the setting of
Pr.05-17toPr.05-31
is too high

Yes

If finished with
executing
Pr.05-15

If the setting of
Pr.05-00 to Pr.05-14
are the same

Is it in PLC mode

Press UP/DOWN key
to see if speed has
any change

If there is any change
of the signal that sets
frequency (0-10V and
4-20mA)

Check if the wiring between
M1~M6 to DCM is correct

Correct
wiring

Check if frequency for
each step is different

Check if the wiring of
external terminal is correct

Change frequencysetting

Check if accel./decel.
time is set correctly

Please set suitable
accel./decel. time by
load inertia

Maybe AC motor drive has malfunction or misoperation
due to noise. Please contact DELTA.

Change defective
potentiometer