Generac Power Systems 53187 User Manual
Page 140
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
SECTION 5.9
TROUBLESHOOTING TEST PROCEDURES
Test 22- Test Low Oil Pressure Switch
(Continued)
PROCEDURE (CONT’D);
1. Set a VOM to its “Rx1" scale and zero the m eter.
2. Unplug W ire 85 from the sw itch term inal.
3. Connect one VOM test lead to the pressure sw jtch
term inal; the second test lead to fram e ground. W ith
engine shut dow n, the m eter should read "continuity".
4. Crank and attem pt to start the engine. As the engine
cranks and attem pts to start, the pressure sw itch con
tacts should open and the m eter should read "infinity".
RESULTS:
1. Replace the low oil pressure sw itch if it fails the tests.
2. If the pressure sw itch checks good, go to Test 23.
I
PARTS
ENGINE ELECTRICAL SYSTEM
Test 23- Test High Coolant Temperature
Switch
DISCUSSION:
The high coolant tem perature sw itch is connected
in parallel, in the sam e circuit as the low oil pressure
sw itch. Failure of the engine to start can be caused by
a defective tem perature sw itch.
PROCEDURE:
Referto
"H igh Coolant T em perature Sw itch"
In Part
5, Section 5.5 (Page 5.5-1).
RESULTS:
Replace tem perature sw itch if it is defective.
PAGE 5.9-8