Authorized service center, United states and international, Cleaning instructions – YSI 9600 User Manual
Page 83
AUTHORIZED SERVICE CENTER
UNITED STATES AND INTERNATIONAL
YSI Incorporated
• Repair Center • 1725 Brannum Lane • Yellow Springs, Ohio • 45387 • Phone: (937)
767-7241 or 800-765-4974
• E-Mail: [email protected]
CLEANING INSTRUCTIONS
NOTE: Before they can be serviced, equipment exposed to biological, radioactive, or toxic materials must
be cleaned and disinfected. Biological contamination is presumed for any instrument, probe, or other device
that has been used with body fluids or tissues, or with wastewater. Radioactive contamination is presumed
for any instrument, probe or other device that has been used near any radioactive source.
If an instrument, probe, or other part is returned or presented for service without a Cleaning Certificate, and
if in our opinion it represents a potential biological or radioactive hazard, our service personnel reserve the
right to withhold service until appropriate cleaning, decontamination, and certification has been completed.
We will contact the sender for instructions as to the disposition of the equipment. Disposition costs will be
the responsibility of the sender.
When service is required, either at the user's facility or at YSI, the following steps must be taken to insure
the safety of our service personnel.
) In a manner appropriate to each device, decontaminate all exposed surfaces, including any containers.
70% isopropyl alcohol is suitable for most disinfecting. Instruments used with wastewater may be
disinfected with 0.5% Lysol if this is more convenient to the user.
) The user shall take normal precautions to prevent radioactive contamination and must use appropriate
decontamination procedures should exposure occur.
) If exposure has occurred, the customer must certify that decontamination has been accomplished and
that no radioactivity is detectable by survey equipment.
) Any product being returned to the YSI Repair Center, should be packed securely to prevent damage.
) Cleaning must be completed and certified on any product before returning it to YSI.
NOTE CAREFULLY: The following steps which are SPECIFIC TO THE 9600 must be performed
prior to shipment of the 9600 to YSI. IF ANY CHEMICALS ARE PRESENT IN THE 9600
ASSEMBLY WHEN RECEIVED BY YSI, IT WILL IMMEDIATELY BE RETURNED AT THE
USER’S EXPENSE.
• Remove the carousel and place on a flat surface.
• Make sure that the pinch clamps on all reagent are closed. Then disconnect the reagent bags
from the 9600 tubing, remove the bags from the monitor and set aside for further use. Do NOT
return the bags with the analyzer. Leave the waste bags connected to the analyzer at this point.
YSI Environmental
83
Model 9600 Nitrate Monitor