Manual settings, Resetting zoom interlocking, Rotation limit selection – Toa C-CC774 PL User Manual
Page 66
![background image](/manuals/714541/66/background.png)
66
11. MANUAL SETTINGS
11.1. Resetting Zoom Interlocking
Rotation speed relative to zoom ratio can be set to OFF. Select OFF when the function of reducing the
rotation speed during telescopic operation is not needed.
1. Select “MANUAL” on the Camera Menu screen, then press the
Set key.
2. Select “ZOOM SCALABLE P/T” on the Manual Settings
screen, then press the Set key.
3. Select “ON” or “OFF” with the joystick, then press the Set key.
The Zoom Interlocking function status is then set.
C A M
C A M E R A M E N U
P R E S E T
I D S E T T I N G
C A M E R A S E T T I N G
A U T O M O D E
A L A R M
A U X
T I M E R
M A N U A L
M A I N T E N A N C E
Camera menu screen
E N G L I S H
L A N G U A G E
Z O O M S C A L A B L E P / T
M A X P / T S P E E D
P / T L I M I T S E T T I N G
*
M A N U A L
*
P / T L I M I T
F L I P
U P L I M I T
1 2 0
O F F
O N
O F F
L E F T
O N
Manual setting screen
11.2. Rotation Limit Selection
Designate the pan and tilt rotation range limits.
OFF:
Disables rotation limits.
ON:
Enables rotation limits. The camera does not tilt between –90° and –185°.
CLEAR:
Deletes all rotation limit positions.
Notes
• Enabling the rotation limit sets the tilt range to between +5° and –185°. The auto-flip function is
automatically disabled.
• Enabling the rotation limit cancels the trace setting.
1. Select “P/T LIMIT” on the Manual Setting screen, then press
the Set key.
2. Select “OFF,” “ON,” or “CLEAR ” with the joystick, then press
the Set key.
The Rotation Limit status is then set.
Z O O M S C A L A B L E P / T
M A X P / T S P E E D
P / T L I M I T S E T T I N G
*
M A N U A L
*
P / T L I M I T
F L I P
U P L I M I T
1 2 0
O F F
O N
O F F
L E F T
O N
Manual setting screen