8.2. Report Setting
Specify the terminal that transmits alarm input information to the controller.
1. On the Alarm Setting screen, select “REPORT”, then press the
Set key.
2. On the Alarm Setting screen, select the number, then press
the Set key.
3. Select “ON” with the joystick, then press the Set key to enable
transmission of alarm input information.
4. Repeat Step 2, 3 to turn the all numbers to which alarm signal
is transmitted “ON.”
Alarm report setting screen
*
A L A R M
*
R E P O R T
- - - - - - - - - - - - - - - - - - - - - - - - - - -
1 : O N
2 : O N
3 : O F F
4 : O F F
6 : O F F
5 : O F F
7 : O F F
8 : O F F
Alarm setting screen
I N P U T
*
A L A R M
*
R E P O R T
A C T I V E S T A T E
P R I O R I T Y
A C T I O N
I N T E R V A L
R E S E T A C T I O N
A L A R M D A T A
4. Select “ON” with the joystick, then press the Set key to enable
alarm reception.
Note: Set to “OFF” when disabling alarm reception.
5. Repeat Step 3, 4 to turn the all numbers to which alarm signal
is input “ON.”
Alarm input setting screen
*
A L A R M
*
I N P U T
- - - - - - - - - - - - - - - - - - - - - - - - - - -
1 : O N
2 : O N
3 : O F F
4 : O F F
6 : O F F
5 : O F F
7 : O F F
8 : O F F